⚡

HOMELAB ARCHITECTURE & NETWORK TOPOLOGY

UniFi 10G/20G Fabric

UDM Pro Max • Bell 3G Symmetric Fiber (GigaHub v1 • Advanced DMZ) • Funnel Optical Core • Unraid 7.4.0 • NASferatu • NASi goreng • 4 VLAN Enclaves

VLAN 1: Trusted
172.16.1.0/24
VLAN 2: Core (Mgmt)
172.16.2.0/24
VLAN 3: Security
172.16.3.0/24
VLAN 10: IoT
172.16.10.0/24
🌐 WAN Edge

Bell Canada 3G Symmetric Fiber

Service: 3 Gbps Up / 3 Gbps Down (Symmetric)
Modem / Gateway: Bell GigaHub v1
WAN Mode: Advanced DMZ (Public IP Pass-Through)
Public IP: 203.0.113.189
Interface: 10G SFP+ Optical Hand-off ➔ UDM Pro Max Port 10
Auto-Speedtest: 06:00 AM Daily
🛡️

UDM PRO MAX

Core Gateway, Router & v2 Firewall Engine
IPS ACTIVE (34 FEEDS)
ROUTING ENGINE Inter-VLAN (L3)
WIRELESS AP MGR 7 Access Points
FIREWALL RULES v2 Policy Engine
UP-LINK PORT 11 10G SFP+ Optical
Trusted: 172.16.1.1 Core: 172.16.2.1 Security: 172.16.3.1 IoT: 172.16.10.1
⚡

FUNNEL • USW-AGGREGATION (10G OPTICAL ROOT CORE)

IP: 172.16.2.233 (VLAN 2 Core) • STP Priority: 0 (Spanning Tree Root) • 8x 10G SFP+
Flow Control: ACTIVE (802.3x) MTU: 1500 (Clean L2)
Grand Central Trunk 20 Gbps LACP
Funnel: Ports 7 & 8 (2x 10G SFP+)
Switch: USW-Pro-Max-24-PoE (Ports 25, 26)
Management IP: 172.16.2.100 (Core)
STP Priority: 4096 (Bridge Root Secondary)
Wifi Aggregation Link 10 Gbps SFP+
Funnel: Port 4 (10G SFP+)
Switch: USW-Flex-2.5G-8-PoE (Port 10)
Management IP: 172.16.2.170 (Core)
STP Priority: 4096
NASferatu Dedicated Pipe 10 Gbps SFP+
Funnel: Port 6 (10G SFP+)
Host: NASferatu (UNAS Pro 7-Bay)
Direct IP: 172.16.1.4 (VLAN 1 Trusted)
Storage Capacity: 67 TB Managed (7x 18TB HDDs • 126 TB Raw)
🚀

UNRAID SERVER (GMKtec K9)

Unraid OS 7.4.0 • IP: 172.16.1.2 (VLAN 1 Trusted) • Fixed DHCP
2x 2.5G LACP (5 Gbps bond0)
CPU Intel Core Ultra 5 125H 14 Cores / 18 Threads
MEMORY 32 GB DDR5 5600 MHz Dual-Channel
HARDWARE TRANSCODING Intel Arc Graphics iGPU QuickSync AV1/HEVC/H264
WAN INGRESS PORTS Plex 32400 | Caddy 8443 Protected Reverse Proxy
Storage Array & Pool Configuration 14 TB Usable Protected Array + Fast NVMe Tiers
Single Parity Protected
🛡️ Parity 8 TB Array Protection (1-Drive Fault Tolerance)
💿 Data 1 8 TB Primary Storage (/mnt/disk1 • XFS)
💿 Data 2 3 TB Array Storage (/mnt/disk2 • XFS)
💿 Data 3 3 TB Array Storage (/mnt/disk3 • XFS)
⚡ Cache Pool 1 TB NVMe Fast NVMe Ingest & Docker AppData
💾 Flash Boot 250 GB NVMe ZFS Mirrored OS Boot & Config Pool
Array Raw Usable: 14 TB (13.7 TiB shfs) Parity Protection: 8 TB Dedicated Parity High-Speed Cache: 1 TB PCIe 4.0 NVMe SSD
Active Docker Microservices (17 Containers) Running on NVMe Cache (/mnt/cache/appdata)
🎬 Media Streaming & Analytics
• plex Intel QSV HW Transcode • Port 32400
• jellyfin Secondary Open-Source Media • Port 8096
• tautulli Plex Activity Analytics & Logs • Port 8181
🔒 Ingress & Network Security
• caddy Auto HTTPS Proxy & Internal DNS • Port 8443
• gluetun WireGuard VPN Tunnel Gateway
• qbittorrent Torrent Client (Routed strictly via Gluetun)
• CloudflaredTunnel Zero Trust Cloudflare Edge Tunnel
• duckdns Dynamic DNS Sync Daemon
🍿 Arr Automation Pipeline
• radarr 4K/1080p Movie Automation • Port 7878
• sonarr TV Series Episode Manager • Port 8989
• bazarr Automated Subtitle Fetcher • Port 6767
• prowlarr Universal Indexer Manager • Port 9696
• binhex-seerr Overseerr Discovery & Requests • Port 5055
• houndarr Indexer Searching & Curation Helper
🌐 Publishing & Monitoring
• ghost-server Headless CMS • Port 2368
• ghost-db MySQL DB Engine for Ghost CMS
• victorialogs Log Aggregator & Microservice Telemetry
💾

NASFERATU (UniFi UNAS Pro 7-Bay)

UniFi Drive OS 6.0.18 • IP: 172.16.1.4 (VLAN 1 Trusted) • Direct SFP+
10 Gbps SFP+ (Funnel Port 6) 67 TB Managed Storage
DRIVE SPECIFICATION 18 TB Enterprise HDDs 17.99 TB / 16.36 TiB Fundamental Size
TOTAL RAW CAPACITY 126 TB Raw (7x 18TB HDDs) All 7 Bays Populated (100%)
CURRENT DATA STORED 21.1 TB Used (31.5%) 45.9 TB Usable Free
NETWORK INTERFACE 10G SFP+ enp0s2 L2 Line-Rate Switch (0% GW Load)
7-Bay Drive Array Architecture All Drives: 7x High-Reliability 18 TB Enterprise HDDs (6 Active + 1x 18TB Hot Spare)
Bay 1 18 TB Media (Data)
Bay 2 18 TB Media (Data)
Bay 3 18 TB Media (Data)
Bay 4 18 TB Media (Parity)
Bay 5 18 TB Backup (P1)
Bay 6 18 TB Backup (Mirror)
Bay 7 18 TB Hot Spare
Primary Media Pool (NFSv3) 54 TB Raw / 50 TiB Pool
Used: 20 TB (41%) Free: 30 TB
RAID Layout: 4x 18 TB HDDs in RAID 5 (3x Data + 1x Parity)
Mount: /mnt/remotes/nas_plex
Tuning: TCP • rsize=1M • wsize=1M • actimeo=60
Volume: .srv/.unifi-drive/plex/.data
📁 /Movies (Radarr 4K) 📁 /TV (Sonarr) 📁 /Music 📁 /Family (Media)
Backup & Archive Drive (SMB 3.1.1) 18 TB Raw / 16.36 TiB Pool
Used: 1.1 TB (7%) Free: 15.9 TB
RAID Layout: 2x 18 TB HDDs in RAID 1 (Mirror Protected)
Share: //STORAGE-CORE/backupDrive
Mount: /mnt/remotes/STORAGE-CORE_backupDrive
Protocol: CIFS 3.1.1 • 1MB buffers • cache=strict
🛡️ Time Machine Backups 💾 AppData Snapshots 🖥️ User Archives
🛡️
Bay 7 Dedicated Hot Spare: 1x 18 TB Enterprise HDD (Online Standby • Instant Auto-Rebuild for Media or Backup Array)
18 TB HOT SPARE ACTIVE
💾

NASI GORENG (UniFi UNAS 2-Bay)

UniFi Drive OS 6.0.18 • IP: 172.16.1.51 (VLAN 1 Trusted) • 2.5GbE PoE+
2.5 Gbps Multi-Gig (GC Port 21) 3 TB Mirrored Storage (6 TB Raw) 16.5W PoE+ Powered
DRIVE SPECIFICATION 2x 3 TB SATA HDDs 6 TB Raw / 3 TB Usable Mirrored
STORAGE POOL CONFIG Dual-Disk Mirrored Pool RAID 1 Mirror Protection
ROLE & FUNCTION Off-Array Replication Independent Snapshot Vault
POWER & NETWORK PoE+ Multi-Gig Line-Rate 16.5W PoE+ Single Cable
2-Bay Drive Array Architecture 2x 3 TB High-Reliability SATA HDD Tier
Bay 1 • 3.5" SATA 3 TB HDD Primary Data Storage & Ingest
Bay 2 • 3.5" SATA 3 TB HDD RAID 1 Mirror (Redundant Fault Protection)
Secondary Mirror & Off-Server Snapshot Tier (SMB 3.1.1 / NFS) Decoupled Resilience
Storage Architecture: 2x 3 TB HDDs in RAID 1 Mirrored Pair (3 TB Usable / 6 TB Raw)
Uplink Interface: Grand Central Switch Port 21 (2.5 Gbps Multi-Gig PoE+)
Primary Purpose: Out-of-band backup target decoupled from Unraid host & primary UNAS Pro array
📁 Secondary System Snapshots 📁 Independent Document Mirror 📁 Cold Standby Failover
📹

SECURITY ENCLAVE (VLAN 3)

172.16.3.0/24 • Air-Gapped (Policy 40001)
TAMPER PROOF
📹 UNVR-Gen-2 GC Port 20 (2.5GbE Native VLAN 3)
172.16.3.2
🔔 Doorbell Lite 3.0W PoE Powered
GC Port 4 PoE (Native VLAN 3)
172.16.3.194
🔔 UP Chime (Protect) Upstairs SE AP (Wi-Fi VNO Tagged)
172.16.3.151
📷 Garage Cam (G5 Turret) 4.6W PoE Powered
Garage switch Port 3 PoE
172.16.3.125
📡 Wireless Cams (G6 Instants) Basement: .149 | Kitchen: .207 | Front: .61
Wi-Fi VNO
• Air-gapped security zone enforced by v2 Firewall Policy 40001.
• Cameras, chime, and NVR strictly isolated from initiating probes into LAN.
🏗️
Planned Expansion (Pending Deployment): 4x G6 Turrets not yet installed (2 in the front, and the other 2 covering the side and backyards).

🖥️ Workstations & Admin Ingress

🎮
Lenovo Legion Tower 7i Gen 10 AI Workstation • Primary Admin
SUPER ADMIN
PROCESSOR (CPU) Intel Core Ultra 9 285K 24C / 24T (8P + 16E up to 5.7 GHz)
GRAPHICS (GPU) NVIDIA RTX™ 5090 32 GB GDDR7 (Blackwell Architecture)
SYSTEM MEMORY (RAM) 64 GB DDR5-5600 2x 32GB Dual-Channel Samsung
NVME STORAGE 2 TB NVMe PCIe 4.0 SK Hynix HFS002TEJ9X162N
Operating System: Windows 11 Pro 64-bit (Build 26300)
IP Address: 172.16.1.3 (Fixed DHCP • VLAN 1 Trusted)
NIC & Uplink: Realtek 2.5GbE LAN • Study Switch Port 3 (2.5 Gbps)
Privileges: Full L3 Core Admin, SSH Root, AI/ML Ingestion, World of Tanks 🎯
🛡️
Pi-hole DNS Server (Dell Wyse 5070) Dedicated Bare Metal Thin Client
PORT 53 SINKHOLE
PROCESSOR (CPU) Intel Pentium Silver J5005 4 Cores / 4 Threads @ 1.50 - 2.80 GHz (10W TDP)
SYSTEM MEMORY (RAM) 8 GB DDR4 ~736 MB Active / 7.8 GB Detected
INTERNAL STORAGE 32 GB eMMC / Flash sda (29.8 GiB) • Ubuntu LVM Volume
DNS DAEMON STATUS Pi-hole Core v6.6 • FTL v6.9 Listening: Port 53 UDP/TCP IPv4+IPv6
Operating System: Ubuntu 24.04.4 LTS (Noble Numbat • Linux 7.0.0-43-generic)
IP Address: 172.16.1.5 (Fixed DHCP • VLAN 1 Trusted)
NIC & Uplink: 1 GbE Gigabit Ethernet (enp1s0) • Study Switch Port 2
Network Function: Network-Wide Primary DNS Resolver & Ad/Tracker Sinkhole
⚡

USP PDU PRO • RACK POWER TELEMETRY

ACTIVE (138V AC)
USP-PDU-Pro • IP: 172.16.1.237 • Grand Central Port 1 • 16 Switched AC Outlets + 4 USB-C
309.8 W Total Draw 16.5% of 1,875W
TOTAL RACK DRAW 309.8 W 2.83 A @ ~138V AC
PDU LOAD CAPACITY 1,875 W 1,565 W Headroom (83.5%)
OUTLET SATURATION 7 / 16 In Use 9 Switched Outlets Standby
DOWNSTREAM POE 80.3 W Total PoE APs, UNAS 2 & Cameras
Rack Power Load: 309.8 W PDU Max Rating: 1,875.0 W (15A Circuit)
Connected Rack Equipment Power Telemetry (Watts / Amps / PF)
🏢
Grand Central Switch (USW-Pro-Max-24-PoE) DUAL FEED
Outlets 5 & 9 • Switch Logic + All Core PoE Delivery
88.73 W 0.764 A (23.0W + 65.7W)
💾
NASferatu (UNAS Pro 7-Bay) OUTLET 13
6x 18TB Enterprise HDDs Active • 10G SFP+ Link
64.55 W 0.551 A • PF 0.85
📶
Wifi Aggregation Switch (Flex-2.5G-8-PoE) OUTLET 7
Switch Logic + 4x U7 APs & 2x Edge Switch PoE Feeds
58.75 W 0.467 A • PF 0.91
📹
UNVR Gen 2 Surveillance Appliance OUTLET 18
Dedicated Surveillance Storage & Continuous 2K/4K Ingest
48.57 W 0.408 A • PF 0.86
🚀
Unraid Media Server (GMKtec K9) OUTLET 15
Intel Core Ultra 5 125H • 17 Microservices • Idle/Load
24.19 W 0.371 A • PF 0.47
🗄️
Sabrent External DAS Enclosure OUTLET 17
Multi-Bay SATA Drive Bay Power Supply
17.57 W 0.163 A • PF 0.78
⚡
Funnel (USW-Aggregation Core Switch) OUTLET 11
8x 10G SFP+ Optical Fabric Routing • High Efficiency
7.42 W 0.109 A • PF 0.49
Sub-Meter: Downstream PoE Delivered by Switches ~80.3 W Included in PDU Draw
NASi goreng 16.5 W (2.5G PoE+)
Garage Switch & Cams 11.6 W (PoE++ 60W)
7x Wi-Fi 7 APs 48.5 W (PoE+ / PoE)
Doorbell & Edge 3.7 W (PoE)
* Note: Peripheral workstations (RTX 5090 Legion, DNS Server, TV streaming boxes) run on independent room branch circuits and are not powered by the rack PDU.
🌐

UNIFI NETWORK TOPOLOGY

WIRED CLIENTS • UNIFI INFRASTRUCTURE
Explicitly showing wired endpoints & UniFi infrastructure hardware only (excludes personal Wi-Fi devices)
WIRED • INFRASTRUCTURE ONLY
Highlight:
WAN • 10G SFP+ ⚲ 11 ➔ 5 10 GbE ⚲ 6 10 GbE ⚲ 7+8 ➔ 25+26 20 GbE ⚲ 4 ➔ 10 10 GbE ⚲ 1 FE ⚲ 2 FE ⚲ 4 FE ⚲ 10 ➔ 1 1 GbE ⚲ 9 ➔ 1 1 GbE ⚲ 19 2.5 GbE ⚲ 20 2.5 GbE ⚲ 21 2.5 GbE ⚲ 23+24 2.5 GbE ⚲ 8 2.5 GbE ⚲ 7 2.5 GbE ⚲ 2 2.5 GbE ⚲ 6 ➔ 5 2.5 GbE ⚲ 1 ➔ 5 2.5 GbE ⚲ 5 2.5 GbE ⚲ 2 1 GbE ⚲ 3 FE ⚲ 2 1 GbE ⚲ 3 2.5 GbE ⚲ 4 FE ⚲ 3 1 GbE ⚲ 4 2.5 GbE 📶 Primary-WLAN 📶 Primary-WLAN 📶 Primary-WLAN 📶 Primary-WLAN Bell Bell Canada GigaHub v1 • ADMZ UDM Pro Max Funnel NASferatu Grand Central Wifi aggregation USP PDU PRO Amazon Fire TV Doorbell Backyard switch Garage switch Basement AP Ch. 11, Ch. 100, Ch... UNVR-Gen-2 NASi-goreng unraid GMKtec K9 7.4.0 Study AP Ch. 6, Ch. 52, Ch... Kitchen AP Ch. 1, Ch. 149, Ch... Living room AP Ch. 11, Ch. 36 Study switch Upstairs NW switch Upstairs SE Ch. 6, Ch. 52 Garage AP Ch. 1, Ch. 149 Garage cam Basement cam -30 dBm, 2.4 GHz Kitchen cam -34 dBm, 2.4 GHz Front entrance cam -30 dBm, 2.4 GHz DNS Server RTX5090 LaserJet M127fn Apple TV 4K Upstairs NW Ch. 11, Ch. 132 UP Chime -53 dBm, 2.4 GHz
Optical Core: 10G / 20G SFP+ Multi-Gig: 2.5 GbE • 5G LACP Gigabit: 1 GbE Copper Fast Ethernet: 100M Copper Wireless Protect: Primary-WLAN 2.4G PoE Active: 14 Powered Endpoints
📶

WI-FI 7 SPECTRUM FABRIC (7 ACCESS POINTS • 802.11be)

SSID: Primary-WLAN (Tri-Band) • IoT-Isolated (2.4G IoT) • Nightly AI Optimized • Dynamic Reassignment
Fast Roaming: ON Multicast: IGMPv3 🤖 Nightly AI: 03:00 AM (Channels Reassigned)
Living room AP
5.3W PoE+ Powered U7-Mesh
Model: UniFi U7 Mesh
IP: 172.16.2.179 (Core)
2.4G: Ch 11 (20M)
5G: Ch 36 (80M UNII-1)
Uplink: Wifi Agg Port 2 (2.5G)
Study AP
8.7W PoE+ Powered U7-Pro
Model: UniFi U7 Pro
IP: 172.16.2.22 (Core)
2.4G: Ch 6 (20M)
5G: Ch 52 DFS (80M UNII-2A)
6G: Ch auto (160M)
Kitchen AP
9.5W PoE+ Powered U7-Pro-Wall
Model: UniFi U7 Pro Wall
IP: 172.16.2.168 (Core)
2.4G: Ch 1 (20M)
5G: Ch 149 (80M UNII-3)
6G: Ch 53 (160M)
Basement AP
8.7W PoE+ Powered U7-Pro
Model: UniFi U7 Pro
IP: 172.16.2.235 (Core)
2.4G: Ch 11 (20M)
5G: Ch 100 DFS (80M UNII-2C)
6G: Ch auto (160M)
Upstairs NW
5.3W PoE+ Powered U7-Mesh
Model: UniFi U7 Mesh
IP: 172.16.2.65 (Core)
2.4G: Ch 11 (20M)
5G: Ch 132 DFS (80M UNII-2C)
Uplink: Upstairs SW Port 4 (2.5G)
Upstairs SE
5.4W PoE+ Powered U7-Mesh
Model: UniFi U7 Mesh
IP: 172.16.2.50 (Core)
2.4G: Ch 6 (20M)
5G: Ch 52 DFS (80M UNII-2A)
Hosts: UP Chime (172.16.3.151)
Garage AP
5.2W PoE Powered UK-Ultra
Model: Swiss Army Knife Ultra
IP: 172.16.2.237 (Core)
2.4G: Ch 1 (20M)
5G: Ch 149 (80M UNII-3)
Uplink: Garage SW Port 2 (1G)
Spectrum Health 5 Clean 80M Channels Active
Interference: < -96 dBm
Contention: 0% Utilization
Nightly AI Optimized
🤖
Nightly Radio AI Channel Optimization: Radio channels (2.4 GHz, 5 GHz DFS, and 6 GHz) are analyzed automatically at 03:00 AM by UniFi Network Radio AI and potentially reassigned to mitigate neighbor interference and radar events. Listed channels represent nominal baseline allocations.
DYNAMIC AI REASSIGNMENT
📦 Dormant Hardware Reserve (Expansion Staging) 2 Units On Hand • Offline Staged
Basement Staged AP #2
not activated U7-Pro
Model: UniFi U7 Pro (Wi-Fi 7 Tri-Band Ceiling AP)
Status: Dormant • Intended for Basement
Deployment Target: Basement Finished Area / Secondary Tri-Band Ingress
Backyard Mesh Reserve
not activated U7-Mesh
Model: UniFi U7 Mesh (Wi-Fi 7 Tabletop / Wall Mesh AP)
Status: Dormant • Intended for Backyard
Deployment Target: Backyard Patio & Garden Dedicated Outdoor Mesh Fill